12 MAY 2017 MATERIALS PERFORMANCE TANK CORROSION CONTROL SUPPLEMENT TO MP Soil-Side Corrosion Causes Premature Failure of Oil Storage Tank Bottom Plates Tank Protection Article A refiner y was experiencing bottom plate underside (soil-side) corrosion of its aboveground storage tanks (ASTs) at an extraordinarily high rate of 1 to 2 mm/y, which resulted in the failure of four tanks within a two-year period that occurred seven years after the refinery was commis- sioned. All four tanks had severely damaged bottom plates, which were constructed of 8-mm thick uncoated carbon steel. Underside corrosion protection for the ASTs was provided by impressed current cathodic protection (ICCP) using a mixed- metal oxide (MMO) grid anode system. The corrosion morphology after the failure revealed severe localized corrosion with large, deep pits found under deposits of orange-red tubercles comprised of iron oxides. In CORROSION 2017 paper no. 9025, "Pre- mature Failure of API 650 Oil Storage Tank Bottom Plates Due to Soil Side Corrosion," authors N. Al Abri, J.R Nair, A. Al Ghafri, and F. Al Mawali describe the failure analysis carried out, which included a review of the design and function of the CP system and metallurgical tests of a failed bottom plate sample. For the ICCP system, the MMO anode grid was placed between a high-density poly- ethylene (HDPE) secondary containment liner and the tank bottom, which sat on a 75-mm thick sand pad. The underside of the bottom plates were uncoated and the CP design was based on 100% bare surface area. The failures occurred between July 2013 and August 2015, and a detailed CP survey was carried out for the storage tanks in Feb- ruary 2016. The results revealed that none of the tanks achieved the NACE SP0193-2016 1 protection criterion of –850 mV instant "off " potential. The potentials varied from –200 to –800 mV vs. a copper/copper sulfate (Cu/ CuSO 4 ) electrode (CSE), with an average "off " potential of –450 mV vs. CSE across all tanks. Since the potentials were not meeting the –850 mV criteria, further investigation was done to understand the possible rea- sons for such low polarized potentials. The authors note that design deficiencies of the ICCP system—primarily the anode depth/ spacing and inappropriate distribution of power feed cables—resulted in a nonuni- form potential profile across the tank bot- tom surface. Also, high current and voltage attenuation along the anode grid did not provide sufficient current and polarization at a distance away from the power feeds. Because an inefficient CP system alone typically doesn't cause such aggravated corrosion, a sample from a failed tank bot- tom was sent to an external laboratory for a detailed metallurgical analysis to identify corrosion products and possible corro- sion mechanisms. A form of underdeposit corrosion (UDC) that can corrode steel at the rate of 1 mm/year is microbiologically influenced corrosion (MIC). X-ray diffraction analysis of the sam- ple plate's soil side indicated the tubercles were made of porous layers or strata con- sisting mainly of iron oxides surrounded by magnetite (Fe 3 O 4 ). The scales appeared to consist of multiple layers. A closer analysis performed on flakes from scale on the pits indicated the probability of iron-oxidizing bacteria (IOB) present in the corrosion, which formed deposits that further aggra- vated the corrosion by forming a differen- tial aeration cell. IOB produce orange-red tubercles of iron oxides and hydroxides by oxidizing ferrous ions from the bulk medium or the substratum. 2 Th e c orrosion rat es obser ved were amplified by the ingress of water, primarily from leaking fire water sprinklers, through gaps between the annular plate and foun- dation , w hich brought in bacteria and corrosive anions such as chlorides and sul- fates. Without an effective CP system and no other means of corrosion control, such as coatings or vapor corrosion inhibitors, the tank floor was exposed to a severe form of bacterial and UDC that led to perforation and loss of inventory. References 1 NACE SP0193-2016 ( formerly RP0193-2001), "External Cathodic Protection of On-Grade Carbon Steel Storage Tank Bottoms" (Hous- ton, TX: NACE, 2016). 2 A.W. Peabody, Peabody's Control of Pipeline Corrosion, 2nd ed., R . Bianchetti, ed. (Hous- ton, TX: NACE International, 2001), pp. 279- 280. Soil side of the failed plate sample. Multiple perforations were seen under the corrosion deposits. A 100 by100 mm hole was observed when layers of metal were removed from the sample's soil side.

Articles in this issue

Archives of this issue

view archives of Materials Performance Supplements - Corrosion Prevention and Control for Tanks 2017